21700 5500Cellule de batterie au lithium-ion mAh: Key Specifications and Battery Pack Applications

Table des matières

21700 5500Cellule de batterie au lithium-ion mAh: Key Specifications and Battery Pack Applications

As demand for high-capacity rechargeable batteries continues to grow, 21700 cylindrical lithium-ion cells are becoming an important option for professional battery pack manufacturers and energy solution providers.

For companies developing lithium-ion battery packs, selecting the right cell involves more than comparing capacity. Tension, capacité de décharge, internal impedance, dimensions, operating temperature and battery management requirements all influence the final system performance.

UN 21700 lithium-ion cell with a minimum standard discharge capacity of 5500mAh and a nominal voltage of 3.636V offers a high-capacity specification for compatible battery pack engineering projects.

Dans cet article, we explore its key technical specifications, performance characteristics, design considerations and potential applications.

1. Qu'est-ce qu'un 21700 Lithium-Ion Battery Cell?

UN 21700 battery cell is a cylindrical rechargeable lithium-ion cell with a nominal form factor of approximately 21mm in diameter and 70mm in height.

Compared with smaller cylindrical formats, le 21700 design provides more internal volume for active materials, making it suitable for battery designs that require a combination of capacity and compact cylindrical packaging.

Pour les fabricants de batteries, 21700 cells can be arranged in series and parallel configurations to achieve the required voltage and capacity.

The final configuration depends on the electrical requirements, espace d'installation disponible, thermal design and battery management system.

2. Key Specifications of a 21700 5500mAh Battery Cell

Understanding the technical parameters is essential when evaluating a lithium-ion cell for a new battery project.

The following specifications provide a reference for battery pack engineering.

Technical Parameter Spécification
Format de cellule 21700 Cylindrique
Chimie des batteries Lithium-ion
Tension nominale 3.636V
Capacité de décharge standard Min.. 5500mAh
Tension de charge 4.2V
Méthode de chargement CC-CV
Courant de charge standard 0.2C
Courant de charge maximal 1C
Maximum Continuous Discharge Rate 2C
Maximum Non-continuous Discharge Rate 3C
Tension de coupure de décharge 2.50V
Initial AC Impedance Max.. 15mΩ
Poids maximal des cellules 74g
Diamètre maximal 21.78mm
Hauteur maximale 71.00mm
Température de charge 0°C à 45°C
Température de décharge -20°C à 60°C

These values should be evaluated under their specified test conditions. Actual battery pack performance depends on the complete system design and operating environment.

3. High Capacity for Battery Pack Development

Capacity is one of the most important factors when selecting lithium-ion cells.

With a minimum standard discharge capacity of 5500mAh, un 21700 cell can provide a high-capacity option for compatible battery pack configurations.

Par exemple, connecting cells in parallel increases the overall capacity, while connecting cells in series increases the pack voltage.

Cependant, the final configuration must be determined by qualified battery engineers according to the required voltage, capacité, actuel, protection strategy and thermal characteristics.

Choosing a suitable cell configuration helps manufacturers develop battery packs that meet their specific project requirements.

4. Understanding Continuous and Non-continuous Discharge

Discharge capability is another important parameter for battery pack applications.

The cell specification defines:

  • Maximum continuous discharge rate: 2C
  • Maximum non-continuous discharge rate: 3C

These two values should not be confused.

Continuous discharge refers to current that can be maintained under the specified operating conditions. Non-continuous discharge refers to a higher current capability that is not intended to be maintained continuously.

Pour un projet de pack batterie, engineers should evaluate the actual operating current, peak current duration, temperature rise and protection settings.

A suitable BMS and thermal management design are essential for safe and reliable battery operation.

5. Charging Method and Operating Temperature

The cell uses a constant-current and constant-voltage charging method, commonly known as CC-CV.

During the charging process, the charger first supplies a controlled constant current. When the cell reaches the specified charging voltage, the charger maintains constant voltage while the charging current gradually decreases.

The specified charging voltage is 4.2V.

The operating temperature ranges are:

  • Chargement: 0°C à 45°C
  • Décharge: -20°C à 60°C

Battery pack designers must consider temperature monitoring, charging control and over-temperature protection when developing the complete system.

Using an appropriate charger and battery management system helps ensure that the cell operates within its specified limits.

6. Why Internal Impedance Matters

Internal impedance influences voltage drop and heat generation when a battery cell delivers current.

The initial AC impedance of this cell is specified at a maximum of 15mΩ under the test conditions described in the specification.

When evaluating cells for battery pack production, manufacturers should consider:

  • Initial impedance consistency
  • Cohérence de la tension des cellules
  • Cohérence des capacités
  • Temperature rise under load
  • Batch-to-batch quality control

For multi-cell battery packs, cell matching and consistent assembly processes are important parts of overall system design.

7. Potential Applications of 21700 Lithium-Ion Cells

Le 21700 cylindrical format can be evaluated for a range of battery pack projects, depending on the electrical requirements and approved end-use applications.

Potential areas for technical evaluation include:

Portable Energy Storage

Portable energy storage products require appropriate cell configurations, charging systems and protection circuits. Battery pack engineers must evaluate the required capacity, output power and operating conditions.

Electric Mobility Battery Packs

Electric mobility battery projects require careful consideration of continuous current, peak current, vibration resistance, thermal management and battery protection.

Cell suitability must be confirmed against the specific vehicle and pack requirements.

Industrial Battery Systems

Industrial battery systems may require customized voltage, capacity and discharge configurations. The cell can be evaluated as part of a professionally engineered battery pack.

Robotics and Automated Equipment

Battery-powered robotics and automated equipment require suitable battery capacity, stable output and reliable protection systems. Engineers should verify operating current, duty cycle and thermal requirements before selecting a cell.

8. Important Considerations Before Selecting a 21700 Cellule

Before purchasing lithium-ion cells for a battery pack project, professional buyers should evaluate several factors.

1. Electrical Compatibility

Confirm that the nominal voltage, tension de charge, discharge current and capacity match the intended battery system.

2. Mechanical Compatibility

Vérifier les dimensions des cellules, holder design, insulation and available installation space.

3. Thermal Management

Evaluate heat generation, espacement des cellules, cooling conditions and temperature monitoring.

4. Système de gestion de batterie

The BMS should provide appropriate overcharge, décharge excessive, overcurrent and temperature protection.

5. Cell Consistency

For mass production, assess capacity matching, cohérence de la tension, impedance consistency and incoming inspection procedures.

6. Supplier Documentation

Request the applicable formal product specification, traceability information, transport documentation and any relevant test reports or certifications.

9. Working with a Professional Battery Pack Supplier

Selecting the right battery cell is only one part of developing a reliable battery solution.

Battery pack manufacturers and system integrators also need to consider cell configuration, connexions électriques, Sélection GTB, conception du boîtier, thermal management and application-specific testing.

YIFANG focuses on lithium battery cells, battery packs and energy storage solutions, supporting B2B customers with product evaluation, technical communication and battery pack OEM/ODM project discussions.

When evaluating a battery cell for your project, providing detailed requirements helps suppliers understand your application and assess technical compatibility.

10. Request a Battery Cell or Battery Pack Quotation

Are you sourcing 21700 lithium-ion cells for a battery pack manufacturing project?

Contact YIFANG and share the following information:

  • Application prévue
  • Required battery cell quantity
  • Target battery pack voltage
  • Required battery capacity
  • Continuous and peak discharge current
  • Battery pack dimensions
  • Project development stage
  • Pays de destination
  • OEM/ODM requirements

Our team can discuss your project requirements and help evaluate suitable battery solutions.

YIFANG – Your Partner for Lithium Battery Cells and Battery Pack Solutions.

Faire défiler vers le haut